A lawn sprinkler head spraying water

Water Swells by One-Eleventh When It Freezes, So Colorado State Extension Says 11 Cubic Feet in Sprinkler Lines Becomes About 12 Cubic Feet of Ice

Water left sitting in buried sprinkler pipe is the reason so many irrigation systems crack over the winter. Colorado State University Extension puts a number on the problem: water expands by one-eleventh as it freezes, so 11 cubic feet of water in the lines becomes about 12 cubic feet of ice. Pipe, fittings and valves have nowhere to put that extra volume, which is why late November is the deadline for getting the water out.

Why Freezing Water Splits Sprinkler Pipe

The figures come from the Colorado State University Extension fact sheet on preparing home sprinkler systems for winter, written by C.E. Swift and M. Higgins and reviewed in August 2025 by Kurt Jones. According to the fact sheet, water contracts as it cools until it reaches 39 degrees Fahrenheit, then begins to expand, and it freezes at 32 degrees.

That expansion of one-eleventh is what turns 11 cubic feet of water into roughly 12 cubic feet of ice. Inside a closed sprinkler line, the growing ice presses against pipe walls, valve bodies and sprinkler heads, which is why the extension service lays out a full drain or blowout as part of fall maintenance.

The water sits deeper than many homeowners expect. Colorado State notes that a system’s stop-and-waste valve may sit about 5 feet down.

Colorado State’s Blowout Numbers

For systems that cannot drain by gravity, Colorado State describes blowing the lines out with compressed air. The fact sheet gives a compressor pressure of 40 to 80 psi, with a maximum of 80 psi for rigid PVC and 50 psi for polyethylene pipe.

The extension service also offers a sizing rule for the compressor: the system’s gallons per minute divided by 7.5 equals the cubic feet per minute of air needed. Its example is a 20 gallon-per-minute zone, which works out to about 2.66 cfm at 30 psi.

Rather than one long blast, Colorado State advises blowing out each zone twice, using two short cycles. The fact sheet also calls for proper eye protection during the job.

A shorter PlantTalk Colorado page on winterizing sprinkler systems, also from Colorado State University Extension, says systems should preferably be blown out by professionals with an air compressor. It warns that poorly handled air pressure, or water left behind, can damage a system. Some systems have manual or automatic drains instead, according to the page.

Protecting the Backflow Preventer

The Colorado State fact sheet says compressed air should never be forced through a backflow device. For a pressure vacuum breaker, it says the ball valves and test cocks should be worked back and forth several times after the blowout, then left half-open for the winter.

For a reduced pressure device, the steps are longer. The fact sheet describes closing the main shutoff slowly, opening test cocks No. 2 and No. 3, draining the water upstream and leaving the isolation ball valves at about 45 degrees through the cold months.

PlantTalk Colorado adds that wrapping a backflow preventer keeps a system operational longer into the fall. It describes insulation wrapped with plastic, extended down to the pipes at ground level and secured with duct tape.

The site has also covered the pressure limits for blowing out a sprinkler system in more detail.

Drip Lines, Hoses and Spigots Need the Same Attention

Drip systems hold water in the same way. The University of Georgia Extension’s drip irrigation winterization checklist, by Dario Chavez, Timothy Coolong, Lenny Wells and Wesley Porter, says drip systems should be winterized before the first freeze and all valves opened, because closed gate and ball valves trap water that can crack during freeze-thaw cycles. The checklist also says screen and sand filters should be drained, inspected and cleaned.

The University of Arkansas Cooperative Extension’s drip checklist recommends removing backflow preventers, filters and pressure reducers and storing them indoors. It also calls for disconnecting any hose or spigot timer, bringing it inside and taking out its batteries, and wrapping exposed pipes, backflow devices or valves that stay outside.

For outdoor faucets, HGTV’s guide to winterizing sprinklers and hoses describes shutting off the interior valve for each faucet, opening the outdoor tap until it stops dripping and the line is empty, and finishing with an insulated foam cover. Hoses, according to the guide, drain best when unwound with the end lower than the reel. A related piece explains why hoses should come off before the forecast hits 32 degrees.

A Late-November Checklist

Taken together, the guidance points to a short list for homeowners at the end of the season:

  • The irrigation water supply is shut off and the main line drained.
  • Each zone is blown out in short cycles, at or under 50 psi for polyethylene pipe and 80 psi for PVC.
  • Compressed air stays out of the backflow preventer, and its valves are left partly open.
  • Drip filters are drained and every valve is opened so no water is trapped.
  • Timers, filters and pressure regulators come indoors.
  • Hoses and outdoor faucets are drained, and the faucets are covered.

Colorado State’s fact sheet also lists running the controller through a minimum cycle once a week among its winter steps.

This article was produced with AI assistance and edited for accuracy against the sources linked above.